Product Description
Inspection report for Micro Sigma 64008 DOM 06/16 Per Vigil 2+ 49976
the container has 425 jumps, since the unit was installed while new. The container has normal wear and tear to its jumps number The Harness looks in a good shape, the leg pads have some dirt on them, the main flaps look in great shape.
The bungee release system looks normal for the amount of jumps. The main risers look good, the elastic for the excess brake line stow looks ok just a bit stretched. The Disk attachment has good integrity and show normal wear for the ump number, the bridle looks normal, the drogue has a hole on the equator that needs to be repaired.
The main A2-330 Serial #12521 DOM 04/17 The lines on the main looks normal, the wear on them is normal, the life left is about 150 jumps
The slider needs to have the grommets replaced since the plastic washers for grommets are cracked, this is a normal occurrence.
Conclusion the system has been taken care off, the wear and tear is normal to the amount of jumps the unit has.